Home › Advice › 1-fasige omvormer op een 3-fasig net: hoe telt de digitale meter?

Technical

Single-phase inverter on a three-phase grid: how does the digital meter count?

Yes. The Fluvius digital meter adds up the three phases. What you export on one phase is offset against consumption on the other two. When single-phase is enough, and when it is not.

Digitale meter die de som van drie fasen telt, met een 1-fasige omvormer op een 3-fasig net

Do you have a three-phase connection? Your inverter does not have to be three-phase. A 5 kW single-phase hybrid inverter on one phase works fine in Flanders, and is often cheaper. The reason lies in how the Fluvius digital meter counts.

The meter adds up the three phases

The digital meter measures each phase separately, but only registers the total. Fluvius says so itself: the meter first adds up export and import across the phases, and only then does the import or the export register move forward. So both never run at the same time.

Example. The inverter supplies 3 kW on L1, the house uses 1.5 kW on L2 and 1.5 kW on L3.
L1: −3 kW · L2: +1.5 kW · L3: +1.5 kW → together 0 kW. The meter stands still: no import, no export.

See it in action

Grid L1L2L3 Digital meter Inverter Home

The inverter supplies 3 kW on L1. The house uses 1.5 kW on L2 and 1.5 kW on L3. Per phase: L1 −3.0, L2 +1.5, L3 +1.5. Together: 0 kW, so no import and no export.

from the solar panels from the grid no current

Physically, the solar power on L1 flows out to the grid, and the power for L2 and L3 comes from the grid. But for your bill, and for the capacity tariff, only the sum counts. In the example you pay nothing, just as if everything were on the same phase.

When is a single-phase inverter enough?

  • For normal household consumption, up to about 6,000 kWh per year.
  • Up to about 16–18 solar panels (a 5 kW inverter, 8 kWp maximum).
  • If you don’t have an electric car that needs to charge fast.

Under the Synergrid rules (C10/11), at most 5 kVA of generation may be connected on a single phase. That is why we always use a 5 kW inverter on single-phase, with an extra three-phase energy meter so that the inverter and battery see the sum of all phases.

When is three-phase better?

  • With an electric car: a charger needs 7 to 11 kW, more than a 5 kW inverter can supply.
  • With high consumption, many panels, or if you also want to shave peaks above 5 kW.
  • If you have an existing installation of more than 8 kWp.

In our system calculator you see both options side by side on a three-phase grid: Budget (single-phase 5 kW) and Powerful (three-phase 10 kW), with the price. Not sure? Send a photo of your meter box and your quarter-hour data from Mijn Fluvius, and we’ll work it out for you.

Source: Fluvius, frequently asked questions about the digital meter.

Read also (NL)

Your quote within 24 hours

Fill in the form or send us a photo of your meter box right away. Free and without obligation.

Within 24 hours if we have your grid type, the distance to the distribution board and photos. After a site visit the price may still change; we always tell you before installation.

WhatsApp+32 479 42 53 57 Emailinfo [at] ht-elektriciteit.be

With your full address we check your roof on satellite images first: orientation, shade and available area. That way you get a first proposal faster.

More details (optional)
How do I know which grid I have?

Look at the main switch below your digital meter and count the poles (terminals or levers side by side).

  • 2 poles: single-phase 230 V
  • 3 or 4 poles: three-phase. The number of poles does not always show whether it is 3×230 V or 400 V + N.
Main switch with 2 poles: single-phase grid
2 poles = single-phase 230 V
Main switch with 4 poles: three-phase grid
4 poles = three-phase (3×230 V or 400 V + N)

Three-phase or not sure? Send us a photo of your meter with the main switch via WhatsApp: our specialist will tell you which grid you have.

We only use your data to answer your request and prepare a quote. See our privacy policy.